1225 SDE puutedimmer

1225 SDE puutedimmer

Standard touch dimmer insert 

Inductive transformers should have at least 85 % nominal load. The total load including the transformer power loss must not exceed 500 VA. 
Memory function (storing of brightness value) 
Electronic overtemperature protection 
Suitable amplifiers: 246 EB (max. 10) When using 246 EB, charge dimmer with minimum capacity. 
Connection of satellite units (combinations possible): Satellite insert ''2-wire'', ref.-no.: 1220 NE Centre plate (ref.-no.: ..1561.07..) has same functionality as on standard touch dimmer insert 
Number of satellite units: unlimited 
Total length of satellite cables: max. 100 m 
Mechanical push-buttons (NO contact, not illuminated) Short operation: On / Off Longer operation: dimming Note: Satellite operation is only possible, when a ''cover'' (centre plate, automatic switch or other suitable cover) is placed on the main unit. 
Illuminated mechanical push-buttons must have a separate N-terminal. The storage of the dimming value (memory function) is not possible with mechanical push-buttons. 
Satellite insert ''3-wire'', ref.-no.: 1223 NE in combination with automatic switch ref.-no.: ..1180.., ..1180-1.., ..1280.., ..1280-1.., presence detector ref.-no.: PMU 360 .. or ceiling automatic switch ref.-no.: DAW 360 .. The main unit must likewise be operated with an automatic switch, presence detector or ceiling automatic switch. Otherwise there is no function! Number of satellite units: max. 10 Total length of satellite cables: max. 100 m Centre plates: Standard centre plate: .. 1561.07 .. Universal centre plate: .. 1561.07 U .. eNet radio centre plate: FM .. 1561.07 .. Standard automatic switch 180°, 1.10 m: .. 1180 .. Universal automatic switch 180°, 1.10 m: .. 1180-1 .. Standard automatic switch 180°, 2.20 m: AS .. 1280 .. Universal automatic switch 180°, 2.20 m: AS .. 1280-1 .. Ceiling automatic switch: DAW 360 .. Presence detector universal: PMU 360 .. Depending on the type of installation, the maximum connected load has to be reduced by: – 10 % for every 5 °C exceededing 25 °C ambient temperature – 15 % for installation in wood, plaster or hollow walls – 20 % for installation in multiple combinations.